Skip to content Skip to footer

 Extend  mission time 

Extending the Mission of Quadruped Robots

Quadruped robots are built to go where people would rather not go. They climb stairs, cross uneven terrain and inspect industrial environments that are difficult, repetitive or unsafe for human operators.

But every mission starts with the same limitation: the energy stored in the battery.

Not all of that energy is available for actual purpose of the mission. Part is used to reach the work area, part for movement, communication and onboard computing, and enough must remain for the return journey. The further the robot travels from its base, the more battery capacity is consumed simply getting there and back.

At some point, the battery starts to define not only runtime, but how much useful work the robot can complete.

The relevant question becomes: How much mission can the robot complete before it has to return for charging?

Carrying more mission energy

The most obvious way to extend runtime is to add more battery capacity. For moderate extensions, that can be a good solution. But additional battery capacity also adds weight, and on a mobile robot every kilogram affects payload, movement and energy consumption.

A fuel-cell range extender takes a different approach.

It does not replace the robot battery. The battery remains responsible for dynamic power demand such as walking, climbing and short power peaks. The fuel cell supplies energy continuously during operation and reduces the rate at which the battery is discharged.

The basic architecture is:

This means a robot with high short-duration power demand does not necessarily need an equally large fuel cell. If the average mission demand is much lower, a 100, 200 or 400 W range extender can already make a meaningful contribution.

For example, if a robot consumes an average of 500 W and a fuel-cell system contributes 180 W continuously, the battery effectively supplies the remaining 320 W while the range extender is operating.

The battery still does what it does best. It simply discharges more slowly.

What that changes during the mission

Consider a robot inspecting a large industrial site. It leaves its base, travels to the inspection area, performs thermal imaging, visual inspection, gas detection or acoustic measurements, and still needs enough energy to return. With limited onboard energy, the mission may end not because the inspection is complete, but because the robot has reached the point where it has to turn around.

Additional mission energy pushes that point further away. The robot can travel further, stay longer in the inspection area, complete more inspection points or support additional sensors without shortening the mission to the same extent.

For industrial plants, tunnels, mines, substations, construction sites or remote infrastructure, that can mean fewer charging interruptions and more useful inspection completed per deployment.

That is the difference between simply increasing runtime and actually extending the mission.

Sizing the range extender around the task

FCT is currently evaluating Lamina-based range-extender configurations between approximately 90 W and 360 W of continuous fuel-cell output.

Fuel-cell power and hydrogen storage can be selected independently. The fuel cell determines how much continuous power is added to the robot, while the hydrogen cylinder determines how long that contribution can be maintained.

System class Fuel-cell output H₂ storage Pressure Operating duration* Est. system weight**
100 W 90 W 2 L 300 bar 8.4 h 3.1 kg
100 W 90 W 3.5 L 350 bar 17.2 h 3.2 kg
200 W 180 W 2 L 300 bar 4.2 h 3.8 kg
200 W 180 W 3.5 L 350 bar 8.6 h 3.9 kg
200 W 180 W 5 L 350 bar 12.3 h 4.1 kg
400 W 360 W 3.5 L 350 bar 4.3 h 6.0 kg
400 W 360 W 5 L 350 bar 6.1 h 6.1 kg

* Duration refers to operation of the fuel-cell system at rated output, not directly to additional robot runtime.

** Preliminary FCT engineering estimates. Final weight depends on housing, mounting, control system and robot-specific integration.

The 200 W-class configuration with a 5 L hydrogen cylinder, for example, provides approximately 2.2 kWh of additional usable electrical energy.

How much extra robot runtime that creates depends on terrain, speed, payload, average power demand and the added system weight. The important point is that the range extender continuously replaces part of the energy that would otherwise come from the battery.

The right question is therefore a little more complex then: How long can a fuel cell extend my missions range.

It is: How can I find the best possible balance between Battery Weight & Size, Fuel Cell Power and Hydrogen Storage size to optimize range, weight & cost.

Keep the hydrogen logistics at the base

The hydrogen supply for a mobile robot can remain comparatively simple because the robot already returns to a known location. That may be a charging dock, workshop, field vehicle or temporary operating base. Hydrogen therefore does not need to be available throughout the inspection area. It only needs to be available where the robot is serviced.

For early deployments, the simplest approach is likely to be a replaceable cylinder. After the mission, the robot returns to base, the cylinder is exchanged, the system is checked and the robot can prepare for the next deployment.

For the current backpack concept, hydrogen cylinders in the 2–5 L range are particularly relevant because they provide meaningful additional energy while keeping the system compact enough for mobile integration.

A single robot can operate with externally supplied cylinders. A small fleet can use a central stock at the operating base. Only when utilisation grows does local filling or hydrogen production become more relevant.

The infrastructure can therefore scale with the deployment rather than being a prerequisite for the first robot.

Start with the mission

A useful range extender should be designed around the actual operating profile.

How much energy does the robot currently use? How long does it operate? Which payloads are installed? How much additional mission time would create a real operational benefit? And how much additional weight can the robot carry without compromising mobility?

From those questions, fuel-cell power and hydrogen storage can be matched to the mission.

The battery remains responsible for the dynamic behaviour of the robot. The fuel cell supplies additional energy during operation. The hydrogen storage determines how much of that energy travels with the robot.

The result is not simply a robot that runs longer. It is a robot that can travel further, inspect longer and return after more of the mission has actually been completed.

More information?

I'm interested in

Interested in extending your operating time?

Tell us a little about your application. We'll estimate the right combination of **fuel-cell power, battery buffer and hydrogen storage** to match your mission.

Typical electrical power during operation.
Maximum power required and for how long. (In minutes)
How long should your system operate without intervention? (In hours)